The Switched CDU 16V-MX Cabinet Power Distribution Unit
combines remote configuration and management with power distribution, power
monitoring and environmental monitoring. Reboot a single or dual-power server
with one command. Receive SNMP alerts when power or environmental conditions
exceed thresholds. Assign users specific access rights to designated outlets
or groups.
This unit removes what some managers
consider to be a critical point of failure, the fuse block. This smaller
unit will give you more flexibility in how and where you mount these CDUs.
Servertech Switched CDU products
provide the flexibility needed for all datacenters and remote sites; including
support for 20-amp or 30-amp power input; 100-120V, 208-240V or European
230V configuration; SSL & SSH security; andSNMP-based input current
monitoring. For cabinets with mid-density servers, this cabinet distribution
unit delivers unparalleled solutions.
Click
here for data brochure
Switched CDU CW-16V-MX Features
Item # |
Available Input Voltages |
Rated Amperage |
Available Input Cord |
Outlets |
Dimensions |
CW-16V1-C20MX |
100-120V
50/60Hz |
20A |
IEC 60320/C20
Power Inlet |
(16) NEMA 5-20R |
39.5" (L)
1.75" (W)
2.25" (D) |
CW-16V2-C20MX |
208-240V
50/60Hz |
20A |
IEC 60320/C20
Power Inlet |
(16) IEC 60320/C13 |
39.5" (L)
1.75" (W)
2.25" (D) |
CW-16VE-C20MX |
230V50/60Hz |
16A |
IEC 60320/C20
Power Inlet |
(16) IEC 60320/C13 |
39.5" (L)
1.75" (W)
2.25" (D) |
Switched CW-16V-MX Technical Specifications
Standards
US & Canada (cTUVus mark) to UL 60950-1:2003
and CAN/CSA 22.2 No. 60950-1-03
European Union (TUVGS mark) to EN 60950-1:2001
FCC Class A, Part 15
CE
EMC - EN 55022 Class A, EN 55024 Communications
10/100 BaseT Ethernet
HTTP/HTTPS
SSLv3/TLSv1
SNMPv2
SSHv2
Telnet
LDAPv3 and LDAPS
TACACS+
RS-232 (Serial) Accessories
Temperature & Humidity Probe Option
EMTH-1-1 Temperature & Humidity Probe, 10’ Power
Cord Options
PTCORD-1 IEC 60320/C19 - NEMA L6-20P (20A Twist-Lock)
10’
PTCORD-2 IEC 60320/C19 - Schuko 10’
PTCORD-3 IEC 60320/C19 - IEC 60309 (BS4343, CEE17) 16/20A Blue (UK Commando)
10’
PTCORD-4 IEC 60320/C19 - BS1363 13A (UK) 10’
PTCORD-5 IEC 60320/C19 - 5-15P (15A Straight-Blade) 10’
PTCORD-6 IEC 60320/C19 - 5-20P (20A Straight-Blade) 10’
PTCORD-7 IEC 60320/C19 - L5-20P (20A Twist-Lock) 10’
PT-ADP-C19 Cable mount IEC 60320/C19 Connector Branch
Circuit Protection
Compliant to UL 60950-1 20 or 30 Amp Power Input
Support 20-amp power input support
- IEC320/C20 power inlet receptacles supports any power cord with IEC320/C19
power connector (PTCORD-XX). 30-amp power input support provides hard-wired
10' cord and appropriate L5-30 or L6-30 plug type. 24-Character
Outlet Receptacles Names
Use the firmware interface (Web or serial) to
edit individual outlet receptacles. Identify each receptacle with the
device's serial number, IP address, asset allocation #, department or
any other method to individually name outlets.
Add a Second Tower
Connect an Expansion Module to any Smart or
Switched CDU to control two power input circuits and 32 managed outlets
(individual or groups) - our exclusive strategy for managing dual power-supply
servers.
Firmware Flash Upgradeable
Access new firmware updates via FTP for new
firmware features and code releases. An update to the firmware does not
affect the status of the power outlets.
HTTP/HTTP's Web Configuration & Control
Use the Sentry Web interface to configure each
unit, including network settings, outlet naming & grouping, SNMP traps
for environmental & power thresholds and firmware updates. Also use the
Web interface to control individual or group outlets and monitor key values,
including amperage load(s), temperature/humidity and other environmental
conditions. SSL security provides a secure HTTPs connection.
Integrate Environmental Monitoring
The EMCU - Environmental Monitor integrates
easily with the Power Tower XL, or other Sentry Remote Power Manager.
Locate the EMCU in the equipment cabinet with a PTXL, link it to the PTXL
and view temperature, humidity, water sensing and dry contact closures
from the same PTXL interface you use to manage and monitor the power.
Integrated Temp/Humidity Probes
Two (2) RJ-style connectors located on the face
panel of the CDU's enclosure provide support for two (2) Integrated Temperature
& Humidity Probes with ten-foot (10') cables provide real-time measurements
in the data center cabinet.
LDAP
LDAP (Lightweight Directory Access Protocol)
is a software protocol for enabling anyone to locate organizations, individuals,
and other resources such as files and devices in a network, whether on
the public Internet or on a corporate intranet. Sentry firmware code 5.3b
and newer includes support for LDAP v3 and is configurable to operate
with any Directory Service. It has been tested with these Directory Services:
Microsoft’s Active Directory, Novell’s eDirectory, OpenLDAP
Load Sense
Individual input current monitoring ("Load Sense")
provides real-time power measurement of the load in amps on each power
inlet, accessible via firmware interface.
Remote Power Control
Individual or group outlet remote power control
to cycle power and reboot any selected server(s) or other network device(s).
Use TCP/IP (HTTP, HTTPS, SSH, Telnet, SNMP) or RS-232 to communicate with
each Sentry and rectify locked-up network devices. Assign outlets to a
group for control of dual-power supply servers and other gear with a single
command. Create an unlimited number of groups with any combination of
outlets associated to each group. Reduce Mean Time to Repair (MTTR) of
a failing server by controlling individual power outlet receptacles to
reboot any selected server or other device.
RS-232 Control
Serial control via any device with a bi-directional
serial port, including a PC, laptop, KVM switch, Console Port Access switch,
or terminal server.
Secure Access - SSH or SSL Protection
Secure Shell (SSH), sometimes known as Secure
Socket Shell, is a Unix-based command interface and protocol for securely
getting access to a remote device. Sentry supports SSHv2. Secure Sockets
Layer (SSL) is a commonly-used protocol for managing the security of a
message transmission on the Internet. SSL is an integral part of most
Web browsers (clients) and Web servers. Sentry supports SSLv3/TLSv1.
SNMP Management & Event Notification
The Sentry family of products supports the Simple
Network Management Protocol (SNMP). This allows network management systems
to use SNMP requests to retrieve information and control power for the
individual outlets. The Sentry includes an SNMP v1 agent supporting standard
MIB I and MIB II objects. A private enterprise MIB extension (Sentry3
MIB) is also supported to provide remote power control. SNMP traps can
be generated for various events, including Input Current Load Thresholds
(min & max), Temperature Thresholds (min & max), Humidity Thresholds (min
& max), water indication, closed contacts (cabinet doors open/close),
as well as notification of any time an outlet status is changed (on/off).
Zero U Enclosure
A vertical enclosure that occupies Zero
Vertical U of rack space in the equipment cabinet. It mounts on the back
rails or in the cavity space of the cabinet.
For
presales questions, ordering information or pricing, call us or click
here to contact Zasmos |